0102030405
Split Phase All in One CATL Battery Energy Storage System
PRODUCT INTRODUCTION
This cutting-edge system is designed to seamlessly integrate with split phase electrical systems, providing a reliable and efficient power storage solution for residential and commercial settings. With advanced technology and superior performance, our all-in-one battery system offers a hassle-free installation process and a compact design, enabling users to maximize their energy storage capacity without the need for multiple components. Whether for backup power, grid-tied applications, or off-grid installations, our split phase all-in-one battery system is the ideal choice for sustainable and dependable energy storage.
FEATURES
-

Split Phase All In One Hybrid System
- CATL LFP Battery,stable and safe
- Modular design, single person can carry and install it
- Global cloud platform & Mobile APP anytime and any where
PRODUCT SPECIFICATIONS
●Battery
| Battery Model | CFS 48100 PF |
| Battery Specification | |
| Battery Capacity | 5 kWh |
| Usable Capacity | 4.5 kWh - Discharge Capacity from 100% to Min SoE |
| Battery Type | LFP (LiFePO4) |
| Rated Voltage | 51.2 V |
| Operating Voltage Range | 44.8 V ~ 56.5 V |
| Communication Interface | CAN & RS-485 |
| Warranty | 10 years performance warranty |
| Operations | |
| Maximum Continuous Charging Current | 50 A |
| Maximum Continuous Discharging Current | 80 A |
| Operating Temperature Range | -10℃ –+ 50℃ |
| Storage Temperature Range | -10℃ –+ 55℃ |
| Altitude | 2000 m |
| Relative Humidity | 0% ~ 90% |
| Cooling Strategy | Natural Cooling |
| BMS | |
| Capacity | 200 / 400 / 600 / 800 Ah |
| Monitored Item | Current; Cell Voltage; Battery Voltage Accuracy; Ambient Temperature; |
| LED User Interface | LED Indication for Battery Status (On, Operational, Standby, Fault,Capacity of SOC) |
| Physical | |
| Weight | 56.5 Kg |
| Dimensions (W x H x D) | 540 x 490 x 240 mm |
| Certificate | FCC Part 15 Class B; UL 1973; Class 9; UN38.3, IP66 / NEMA 3R |
●Inverter
| Hybrid Inverter Model | E8KD | E10KD | E12KD | E15KD |
| PV Input | ||||
| Recommended Max. PV Array Input Power @STC | 16 kWp | 18 kWp | 22 kWp | 25 kWp |
| Max. PV Input Voltage | 500 Vdc | |||
| MPPT Voltage Range | 120 ~ 425 Vdc | |||
| Start Voltage | 120 V | |||
| Nominal Voltage | 380 Vdc | |||
| MPPT Voltage Range With Full Load | 200 ~ 425 V | 240 ~ 425 V | 200 ~ 425 V | 240 ~ 425 V |
| Number of MPPT Tracker | 2 | 2 | 3 | 3 |
| Max. Input Current | 30 A*2 | 30 A*2 | 30 A*3 | 30 A*3 |
| Max. Short-circuit Current | 40 A*2 | 40 A*2 | 40 A*3 | 40 A*3 |
| AC Output ( On Grid) | ||||
| Nominal (L-L) Output Voltage | 240 / 208 V | |||
| Output Voltage Range | 160 V~ 300 Vac(L~L) | |||
| Output Frequency | 50 / 60Hz (±5Hz), (Adjustable) | |||
| Nominal Output Current | 33.4 A | 41.7 A | 50 A | 62.5 A |
| Max. Output Power | 8 kVA | 10 kVA | 12 kVA | 15 kVA |
| Nominal Output Power | 8 kW | 10 kW | 12 kW | 15 kW |
| Output Connection | Split phase, 2/3 phase, single phase, transformerless | |||
| Power Factor (cosΦ) | 0.8 leading - 0.8 lagging(Adjustable) | |||
| THDi | < 3% | |||
| AC Output (Backup) | ||||
| Nominal (L-L) Output Voltage | 240 / 208 V | |||
| Nominal Output Frequency | 50 / 60 Hz(±0.2%) | |||
| Nominal Output Current | 33.4 A(RMS) | 41.7 A(RMS) | 50 A(RMS) | 50 A(RMS) |
| Nominal Output Power(Daytime) | 8 kW | 10 kW | 12 kW | 12 kW |
| Max. Output Power(Daytime) | 8 kVA | 10 kVA | 12 kVA | 12 kVA |
| Nominal Output Power(Nighttime) | 7.36 kW | 9.2 kW | 11 kW | 11 kW |
| Max. Output Power(Nighttime) | 8 kVA | 10 kVA | 12 kVA | 12 kVA |
| THDv | < 2%(Linear load) | |||
| On / Off Gird Switching Time | < 20 ms | |||
| Over Current Protection | 50 A / pole | 60 A / pole | 75 A / pole | 100 A / pole |
| Battery Input | ||||
| Battery Type | Lithium battery | |||
| Battery Nominal Voltage | 51.2 V | |||
| Battery Voltage Range | 44 ~ 58 V | |||
| Depth Of Discharge | 90% DOD (10% ~ 90% Adjustable) | |||
| Max. Discharging Current | 200 A | 200 A | 240 A | 240 A |
| Max. Charging Current | 160 A (Adjustable) | 160 A (Adjustable) | 200 A (Adjustable) | 200 A (Adjustable) |
| Max. Discharging Power | 8 kW | 10 kW | 12 kW | 12 kW |
| Max. Charging Power | 8 kW | 8 kW | 10 kW | 10 kW |
| Battery Switch | Single - pole DC switch (2*200 A / Pole) | |||
| Capacity | 200 / 400 / 600 / 800 Ah | |||
| Efficiency | ||||
| CEC Efficiency | 97.5% (@240 V) / 96%(@208 V) | 97.5% (@240 V) / 96%(@208 V) | 97% (@240 V) / 96%(@208 V) | 97% (@240 V) / 95.5%(@208 V) |
| MPPT Efficiency | > 99.9% | |||
| General Specifications | ||||
| Cooling Type | Intelligent air cooling | |||
| DC Switch | Optional | |||
| Communication Port | RS-485 / CAN 2.0 / WIFI | |||
| Protection Class | Class II | |||
| Operating Temperature Range | -25℃ ~+ 60℃ (Rated power@40℃ ) | |||
| Storage Humidity Range | 0 ~ 95% (No Condensation) | |||
| Operating Altitude | ≤ 2000 m | |||
| Overvoltage Type | II(DC side);III(AC side) | |||
| IP Class | IP65 / 3R | |||
| Weight | 73 kg | |||
| Dimensions (W x H x D) | 540 x 1050 x 240 | |||
| Protection & Certifications | ||||
| Certifications | Electronics Certified Safety by SGS Labs to NEC & UL Specs - NEC 690.4B & NEC 705.4/6 | |||
| Grid Sell Back — UL 1741 - 2010/2018;IEEE 1547a - 2003/2014;FCC 15 Class B; | ||||
| UL 1741 SB;CA Rule21;HECO Rule 14 H | ||||
| Protection | PV DC Disconnect Switch — NEC 240.15 | |||
| Ground Fault Detection — NEC 690.5 | ||||
| PV Rapid Shutdown Control — NEC 690.12 | ||||
| PV Arc Fault Detection — NEC 690.11 | ||||
| PV Input Lightning Protection | ||||
| PV String Input Reverse Polarity Protection | ||||
| AC Output Breakers | ||||
| Battery Breaker / Disconnect | ||||
| Surge Protection | ||||